Controversial topics in orthopaedics: ceramic-on-ceramic.
HS Sandhu, RG Middleton - Annals of the Royal College of …, 2005 - ncbi.nlm.nih.gov
Sandhu and Middleton argue that ceramics have superior biomechanical properties of low
wear and friction. These characteristics are off-set by the cost, poor tolerance to implant …
wear and friction. These characteristics are off-set by the cost, poor tolerance to implant …
Prolonged operative time increases risk of blood loss and transfusion requirements in revision hip surgery
J Manara, H Sandhu, M Wee, A Odutola… - European Journal of …, 2020 - Springer
Introduction Revision hip surgery is well documented to have a high association with
substantial blood loss and the associated need for a blood transfusion. This exposes the …
substantial blood loss and the associated need for a blood transfusion. This exposes the …
Leg length discrepancy in total hip arthroplasty with the use of cemented and uncemented femoral stems. A prospective radiological study
R Ahmad, V Sharma, H Sandhu… - Hip International, 2009 - journals.sagepub.com
Leg length discrepancy may occur following total hip arthroplasty, with a potentially impaired
functional outcome as a result. The aim of this study was to compare the leg length …
functional outcome as a result. The aim of this study was to compare the leg length …
Acetabular Cement Mantles and Component position: are we achieving “ideal” results?
HS Sandhu, WN Martin, M Bishay, JL Pozo - The Journal of arthroplasty, 2006 - Elsevier
Radiographs of 100 primary cemented total hip arthroplasties were studied. Acetabular
component positioning and cement mantles were assessed with respect to implant type …
component positioning and cement mantles were assessed with respect to implant type …
Cable plating with a single strut allograft in the treatment of periprosthetic fractures of the femur
JR Manara, JA Mathews, HS Sandhu - Hip International, 2019 - journals.sagepub.com
Background: Hip arthroplasties are increasing worldwide resulting in an increasing number
of periprosthetic fractures. These fractures are difficult to treat with various the different …
of periprosthetic fractures. These fractures are difficult to treat with various the different …
[PDF][PDF] Haemorrhagic Pseudotumour Following Metal-on-Metal Hip Replacement
JL Filer, J Berstock, Y Hughes-Roberts, J Foote… - Cureus, 2021 - cureus.com
We present a unique report of a spontaneous haemorrhage into a pseudotumour five years
following revision surgery for failed metal-on-metal hip arthroplasty. The patient sustained …
following revision surgery for failed metal-on-metal hip arthroplasty. The patient sustained …
Improving the accuracy of digital templating: achieving success through stakeholder management
H Parwaiz, BA Crespo, J Filer, A Thorpe… - BMJ Open …, 2019 - bmjopenquality.bmj.com
The use of a marker ball in digital templating for hip arthroplasty is a well-established
method of preoperative planning and is used to overcome the inherent magnification in plain …
method of preoperative planning and is used to overcome the inherent magnification in plain …
Hip pain in a 38-year-old man
HS Sandhu, AC Ross, L Robinson… - Clinical Orthopaedics …, 2004 - journals.lww.com
On completion of this activity, the reader should be able to: 1) recall that osteopoikilosis,
although a potentially benign inherited disorder, has potential malignance sequelae; 2) …
although a potentially benign inherited disorder, has potential malignance sequelae; 2) …