Table 1

Characteristics of included studies

Author(s), year, countryAimDesignSetting and participantsSample sizeOutcomes regarding fluid balance monitoringKey findings
Aitken et al, (2013); UK32AKI Quality of careCohort studyMedical, surgical, AKI243Adequate FBD (%),
inaccurate FB chart (%)
51.8% of patients with AKI had adequate FBD;
43.4% of the remainder had inaccurate FB charts in case notes.
Alexander and Allen (2011) USA33Policy for FB monitoringQuasi-experimentalMedical oncology units427Compliance with FBDBefore intervention, 12% of patients with indication of FB monitoring had FBD vs 84% after.
Asfour (2016); Egypt52Accuracy of FB monitoringCross-sectionalICU except dialysis100Accuracy of calculated FB compared with researcher’s calculation65% of FB charts were accurate and 35% were inaccurate.
Baird et al, (2019); UK42AKI prediction scoreQuasi-experimentalOrthopaedic surgery78FB monitoring (%)Before intervention, 62% had adequate FB monitoring postoperatively vs 66% after.
Davies et al, (2017); UK43Reduce AKI alertsQuasi-experimentalOrthopaedic trauma75Running hourly input, 6 hourly input subtotal, 6 hourly output subtotal and 24-hour total FBBefore intervention, 80% had running 1 hour totals vs 96% after; 36% had 6 hour output vs 68% after. Before intervention, 12% had 24-hour totals vs 72% after and 32% after 6 months.
Davies et al, (2019); Australia*44Relationship between calculated FB and BWProspective cohort studyICU, requiring CRRT61FB charts with calculation errors (%), median deviation in millilitresCalculation errors prevalent in 27% of charts.
Median daily calculation error: 58 mL (range 1–1464 mL). Median cumulative calculation error: 131 mL (range 1–2405 mL).
Diacon and Bell (2014);
South Africa34
FB monitoring and measurement accuracyCross-sectionalICU103FBD (%), calculation errors (%), deviation in millilitres95.1% had FBD. Calculation errors: 68.9% deviated 0–500 mL, 13.5% 500–1000 mL, 6.8% 1001–2000 mL, 5.8%>2000 mL
Eastwood et al, (2012); Australia35Patients receiving IV fluids (%)Cross-sectionalAll inpatients except ICU, ED and PACU326Percentage with FB charts maintained (%)94% of patients receiving intravenous fluids had FB charts vs 44% receiving no intravenous fluids.
Herrod et al, (2010); UK36Prevalence of dysnatraemias and precipitating factorsCross-sectionalSurgery
Na<130 or
>150 mmol/L
55Complete FB charts (%)
Charts with FB calculated (%), median inaccuracy in FB calculation
28% had complete FB charts before dysnatraemia vs 44% after; 37% of charts had no FB calculation. Median calculation error: 72 mL (IQR 9–313 mL) before dysnatraemia vs 130 mL (IQR 71–400 mL) after
Joslin et al, (2015); UK45AKI recognition and managementQuasi-experimentalAKI192Complete FB chart on first day of AKI (%),
days with complete FBD (%)
Before intervention, 25% had completed FB charts on first day of AKI vs 34% (p=0.23) after. Before intervention, FBD was completed in 32% of patient days vs 45% after (p=0.002).
Liaw and Goh (2018); Singapore46Fluid intake chartingQuasi-experimentalAcute surgery60Deduction of input/output at midday and over 24 hours. Calculation of 24 hours FB. Involving patients in fluid intake documentationBefore intervention, 3.3% of the FB charts were complete (midday and 24 hours totalling) vs 100% 1 month and 6 months later. Before intervention, patients were involved in 10% of cases vs 87% 1 month later and 83% 6 months later.
Lim et al, (2021); Singapore53Ordering and documenting fluid in- and outputCross-sectionalAcute care hospital2199Accuracy of FBD defined by recording in millilitresOverall accuracy 77%. Oral and intravenous fluids 100% accurate, output accurate in 21% of cases
Madu et al, (2021); UK54Chart completeness and accuracyQuasi-experimentalGeneral medicine82Accurate measurements, calculation errors, complete documentationBefore intervention, 25% of measurements were accurate vs 39% after 1 month and 5% after 6 months, correct daily totals in 20% vs 40% after 1 month and 15% after 6 months, 14% of charts complete vs 31% after 1 month and 5% after 6 months
Møller et al. (2013); Denmark37Quality improvementProspective cohort studyAcute surgery,
PPU
1650Quality-of-care indicator: daily FBDBefore intervention, 74% had FBD vs 79% after.
RR 1.07 (95% CI 1.02 to 1.13; p=0.010)
Perren et al, (2011); Switzerland*38Accuracy of FBD; agreement w BWCross-sectionalICU147Complete FB charts,
FB charts with calculation errors
12% were excluded due to an incomplete FB chart;
33% of nurse-registered cumulative FB was inaccurate, errors: −3606 mL to +2020 mL. Mean absolute error of 445±668 mL
Pinnington et al, (2016); UK47Complete FBDQuasi-experimentalThree wards120Complete FB chartsBefore intervention, 32% of FB charts were completed correctly vs 92% after. In AKI patients, 20% had FBD before vs 91% after.
Szmuda et al, (2014); Poland39Calculation errors;
FBD and chart completeness
Cross-sectionalNICU and NHDU, SAH41Complete FB charts,
FB miscalculations
63.4% of FB charts were complete, 80.2% in NICU and 58.7% in NHDU (p<0.01). Fluid intake miscalculations in 27.4% of charts. Most common errors: underestimating intake (80.6%), omitting drugs (66.9%)
Tura et al. (2020); Ethiopia48Managing postpartum haemorrhageCross-sectionalObstetric45Standard of care criteria: fluid intake/output chart is maintainedIn 13.3%, a fluid intake/output chart was maintained.
Vincent and Mahendiran (2015); UK49Quality of FB monitoringQuasi-experimentalGeneral medicine147FBD, indication of FBD. Chart completion: boxes filled of all total boxes. Accurate totals=<10% errorBefore intervention, 67% were on FBD (indicated in 53%) vs 38% after (indicated in 93%). Average chart completion rate before intervention was 50% vs 70% after. Average chart accuracy was 41% before vs 61% after.
Wakeling (2011); UK40FBD and FB complications; Hydrant drinking aidQuasi-experimentalOrthopaedic, surgery, urology313Complete FB charts (%)Before intervention, 19%–50% of FB charts were complete vs 29–62% after. Completeness improved (5–18 percentage points).
Walker et al. (2012); UK41Improve guideline adherenceQuasi-experimentalAcute wards101Completion of FB chartsBefore intervention, 62.3% had FBD vs 70.8% after (p=0.36).
Yang et al, (2019); Taiwan51Compliance with FB monitoringQuasi-experimentalCongestive heart failure24FB charts used with electrolytes and physical assessment. Patients involved in FBDBefore intervention, 58% had FB charts with physical assessment vs 100% after; 42% were involved in recording before intervention vs 75% immediately after.
Zhu et al, (2018); China50Non-pharmacological fever managementQuasi-experimentalInfectious disease, HIV60Formal assessment of fluid in- and output volume documentedBefore intervention, 0% had fluid input/output documented vs 73% 10 days after intervention.
  • *Studies addressing cumulative fluid balance.

  • AKI, acute kidney injury; BW, body weight; CRRT, continuous renal replacement therapy; ED, emergency department; FB, fluid balance; FBD, fluid balance documentation; ICU, intensive care unit; NHDU, neurosurgical high-dependency unit; NICU, neurosurgical ICU; PACU, postanaesthetic care unit; PPU, perforated peptic ulcer; SAH, subarachnoid haemorrhage.