Table 2

Equipment setup accuracy. Three items common to the pre and post intervention assessments are presented (rows 2-4). Additionally, two items unique to the pre-intervention and two items unique to the post-intervention set up are presented (rows 7-10).

Preintervention (n=17*)Postintervention (n=18*)Difference (95% CI)P value
Infusion pump setup with dexmedetomidine6/17, 35%13/18, 72%37% (6 to 68)0.028
Atomizer, 10 mL syringe, 2% lidocaine assembled12/17, 71%17/18, 94%24% (2 to 48)0.061
FOB defogged, lubricated and Parker ETT loaded12/17, 71%16/18, 89%18% (8 to 44)0.18
Total common items correct30/51, 59%46/54, 85%26% (10 to 43)0.003
Total error-free setups of common items3/17, 18%12/18, 67%49% (21 to 77)0.003
20 g PIV, 5 mL syringe5/17, 29%n/an/a
Syringe, 30 g needle, lidocaine3/17, 18%n/an/a
4×4 gauze18/18, 100%n/an/a
FOB placed at head of OR bed16/18, 89%n/an/a
Total overall correct (common and unique items)38/85, 48%80/90, 89%41%n/a
Total error free setups (common and unique items)0/17, 0%11/18, 61%61%n/a
  • Bold numbers indicate total critical steps and error free setups when only looking at steps common in the pre and post intervention simulations.

  • *Data were mistakenly not collected for three preintervention and two postintervention simulations.