%0 Journal Article %A Richard J Czosek %A James Brown %A Diane Proctor %A Paula Koch %A Michelle Martin %A Mary Rust %A Jeffrey B Anderson %T Improvement in patient and physician notification of cardiac rhythm device report transmissions %D 2017 %R 10.1136/bmjoq-2017-000155 %J BMJ Open Quality %P e000155 %V 6 %N 2 %X Background Cardiac rhythm devices (CRD) require complex management to identify potential device or patient issues. While easy to obtain, report processing is complex and time consuming. In our population, a majority of reports were performed outside of institutional protocols and no method for electrophysiology (EP) notification for unscheduled reports existed. These process breakdowns led to potential issues with safety and associated loss of work efficiency. Objective Our aim was to decrease the percentage of reports without EP notification from 30% to 10% over a 9-month time period. Methods We created a detailed process map of in-office and home device reporting. Failure mode and effects analysis (FMEA)/Pareto charts were used to determine the mechanistic underpinnings of notification failures and identify areas for process improvement. Multiple interventions were implemented using the Plan-Do-Study-Act (PDSA) technique. Process run charts and control charts were used to evaluate ongoing changes. Results Our FMEA identified failures related to (1) lack of physician understanding of the device reporting system, (2) lack of an easy to use method of EP notification and (3) lack of patient understanding of report notification. Pareto charts identified the most frequent failures to be associated with specific cardiology subspecialties as well as reports sent from home. We performed multiple interventions including(1) creation of an easy to use method of EP notification used by patients and medical staff, (2) physician education and (3) patient education. Compared with baseline reporting, there was a decrease from 30% to <10% of device reports obtained without EP notification. This process improvement additionally resulted in a 34% reduction in time required for device processing. Conclusions Development of a unified EP reporting system and quality improvement methodology resulted in improved CRD report notification and improved efficiency for staff. These process changes resulted in improvement across differing cardiac subspecialty providers and patients. %U https://bmjopenquality.bmj.com/content/bmjqir/6/2/e000155.full.pdf