PT - JOURNAL ARTICLE AU - Sumanjit Gill TI - Reducing door to needle time for stroke thrombolysis AID - 10.1136/bmjquality.u204771.w2199 DP - 2014 Jan 01 TA - BMJ Quality Improvement Reports PG - u204771.w2199 VI - 3 IP - 1 4099 - http://bmjopenquality.bmj.com/content/3/1/u204771.w2199.short 4100 - http://bmjopenquality.bmj.com/content/3/1/u204771.w2199.full SO - BMJ Qual Improv Report2014 Jan 01; 3 AB - Better outcomes are obtained with stroke thrombolysis the more rapidly it is given, both in terms of the patient's level of functional ability and also mortality. Current UK performance targets (outside London) aim for a time of 45 minutes or less. Thrombolysis pathways involve multidisciplinary working across departmental boundaries as well as senior level decision making. Our system used telemedicine out of hours adding additional complexity to the pathway. The initial planning stages started by auditing current practice and mapping the existing pathway. The figures for door to needle times were held on a database on the stroke unit and collected in detail for the purposes of national reporting. The pathway was mapped by combining personal experience of working within the stroke service with the experiences of the general medical registrars who worked the system out of hours. The initial action was to present this information throughout the hospital at departmental meetings. Opinions were canvassed at these meetings on where the biggest barriers were within the pathway and how we could address them. An awareness campaign was held by advertising over the intranet. An intervention comprising the following elements was introduced over the period of a year: introduction of an ambulance pre-alert, revision of the existing pathway, and education to all those involved in thrombolysis. The cases where particularly long delays were noted were audited in more depth to identify barriers to flow through the system. This was reported in ward meetings for staff to contribute experience and to offer solutions. We went to commissioning group meetings to gain the support of the local ambulance service, and talked to A&E seniors about the project and the ways in which they could help. Median times were calculated from a stroke database. There was a fall in median door to needle time of 65.5 to 49 minutes over a period of 18 months. A complex intervention to improve door to needle time can and did produce good results with a reduction in times to within the London performance standards of care. The efficacy could be improved with an increased staffing level and provision of a formal setting within which to discuss changes and to keep up the momentum of change.