Article Text

Download PDFPDF

Using the Safer Clinical Systems approach and Model for Improvement methodology to decrease Venous Thrombo-Embolism in Elective Surgical Patients
  1. Angela Humphries,
  2. Carol Peden,
  3. Lesley Jordan,
  4. Josephine Crowe,
  5. Carol Peden
  1. Royal United Hospitals Bath, NHS Foundation Trust, United Kingdom
  1. Correspondence to Angela Humphries angelahumphries{at}nhs.net

Abstract

A significant incidence of post-procedural deep vein thrombosis (DVT) and pulmonary embolus (PE) was identified in patients undergoing surgery at our hospital. Investigation showed an unreliable peri-operative process leading to patients receiving incorrect or missed venous thromboembolism (VTE) prophylaxis. The Trust had previously participated in a project funded by the Health Foundation using the “Safer Clinical Systems” methodology to assess, diagnose, appraise options, and implement interventions to improve a high risk medication pathway. We applied the methodology from that study to this cohort of patients demonstrating that the same approach could be applied in a different context.

Interventions were linked to the greatest hazards and risks identified during the diagnostic phase. This showed that many surgical elective patients had no VTE risk assessment completed pre-operatively, leading to missed or delayed doses of VTE prophylaxis post-operatively. Collaborative work with stakeholders led to the development of a new process to ensure completion of the VTE risk assessment prior to surgery, which was implemented using the Model for Improvement methodology. The process was supported by the inclusion of a VTE check in the Sign Out element of the WHO Surgical Safety Checklist at the end of surgery, which also ensured that appropriate prophylaxis was prescribed. A standardised operation note including the post-operative VTE plan will be implemented in the near future. At the end of the project VTE risk assessments were completed for 100% of elective surgical patients on admission, compared with 40% in the baseline data.

Baseline data also revealed that processes for chemical and mechanical prophylaxis were not reliable. Hospital wide interventions included standardisation of mechanical prophylaxis devices and anti-thromboembolic stockings (resulting in a cost saving of £52,000), and a Trust wide awareness and education programme. The education included increased emphasis on use of mechanical prophylaxis when chemical prophylaxis was contraindicated. VTE guidelines were also included in the existing junior Doctor guideline App. and a “CLOTS” anticoagulation webpage was developed and published on the hospital intranet.

The improvement in VTE processes resulted in an 80% reduction in hospital associated thrombosis following surgery from 0.2% in January 2014 to 0.04% in December 2015 and a reduction in the number of all hospital associated VTE from a baseline median of 9 per month as of January 2014 to a median of 1 per month by December 2015.

This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: